Logo

Steel

Spectrum Series


spectrum series

Description:
Overview:
Ambient Temperature -10 to +50C Altitude Not exceeding 1000mtrs above mean sea level. Atmosphere Non corrosive & non hazardous Relative Humidity Up to 100% Voltage 415V10% , 3 pH Frequency 50Hz 5% Combined Variation 10% Duty S1 (continuous) Service factor 1.0

Features:  Starting Star Delta/DOL (with shorting links but with 2 entries) Permissible starts/hr. Cold successive - 4 hot successive - 3 equally spread - 6 Loading at reduced volts 75% Rated volts for 5 minutes Insulation / temp.rise Class `F' / 70 deg. C Direction of rotation Bi-directional No. Of leads 6 Connection. Delta Degree of protection IP 55 Method of cooling IC 411 T.box position RHS looking from driving end Bearing life (90% survival basis) 40,000 working hrs. For direct drive 20,000 working hrs. For belt drive Vibration Normal class as per IS 12075 Noise As per IS 12065 Construction Foot, 'B' flange, Foot cum 'B' flange Frame sizes SC 180 to 355 (For 'B' flange mounting, ratings covered in SC180M to be offered in VSC180L, & ratings covered in SC225S to be offered in VSC225M) Shaft extension Single cylindrical extension as per IS: 1231 Body material Cast iron T.box material Cast iron up to 225 frame, mild steel for 250 to 355 frame Fan material Polypropelene for 4, 6, & 8 pole & cast iron for 2 pole up to 225 frames. Mild steel for 250 to 355 frames for all polarities Accessories Nil Paint & shade NC base RAL5012 shade up to 225, Epoxy base RAL5012 above 225 frame Bearing type and Greasing facility Open type bearings for SC180 to 355 Online greasing facility for SC180 to 355


Crane Duty Motor(Slipring)



Description:
Overview:
Ambient Temperature -10 to +50C Altitude Not exceeding 1000mtrs above mean sea level. Atmosphere Non Corrosive & non Hazardous Relative Humidity Up to 100% Voltage 415V 10%, 3 Ph. Frequency 50Hz 5% Combined Variation 10% Duty S3,S4 & S5 (Refer KHD-50-33R2) Service factor 1.0

Features:  Starting DOL up to 100 & Star Delta for 112 above frames Permissible starts/hr Cold successive - 4 hot successive - 3 equally spread - 6 Loading at reduced volts 75% Rated volts for 5 minutes. Insulation / temp.rise Class `F' / 70C Direction of rotation Bi-directional No. Of leads 3 up to 100 & 6 for frame 112 & above Connection Star Up to 90 frame, 6, & 8 pole ratings of 100 Frames Delta 2 & 4 pole ratings of 100 frame & 112 and above all ratings Degree of protection IP 55 Method of cooling IC 411 T.box position RHS looking from DE (towards DE up to 160). Bearing life (90% survival basis) 40,000 working hrs. For direct drive 20,000 working hrs. For belt drive Vibration Normal class as per IS: 12075 Noise As per IS: 12065 Construction Foot / 'B' flange Frame sizes 'ePM80 to 160', 'eSC180 to 355'.(For 'B' flange mounting ratings covered in 'eSC180M' to be offered in 'eVSC180L', & ratings covered in 'eSC225S' to be offered in 'eVSC225M') Shaft extension Single cylindrical extension as per IS: 1231 Body material Cast iron T.box material Cast iron Fan material Aluminium up to 160, Cast iron for 180 225, mild steel for 250 to 355 Frames Accessories Nil Paint & shade Epoxy base RAL5012 Bearing type Greasing facility Prelubricated sealed bearing from 80-160. Open type Bearing from 180. Online greasing facility is for 180 to 355 only


Crane Duty Cage Motors


Crane Duty Motors

Description:
Overview:
Ambient Temperature -10 to +50C Altitude Not exceeding 1000mtrs above mean sea level. Atmosphere Non corrosive & non Hazardous Relative Humidity Up to 100% Voltage 415V 10%, 3 Ph. Frequency 50Hz 5% Combined Variation 10% Duty S3, S4 & S5 Service factor 1.0

Features:  Starting DOL Loading at reduced volts 75% Rated volts for 5 minutes. Insulation Class `F' Temp rise 'F' Direction of rotation Bi-directional No. Of leads 3 up to 100 Frame, 6 for 112 and above Frames Degree of protection IP 55 Method of cooling IC 411 T.box position Side (RHS looking from DE, towards DE) Bearing life (90% survival basis) 40,000 working hrs. For direct drive 20,000 working hrs. For belt drive Vibration Normal class as per IS 12075 Noise As per IS 12065 Construction Foot Frame sizes 80 to 225 Shaft extension Single cylindrical extension as per IS 1231 Body material Aluminium up to 112, cast iron above 112 Frames T.box material Cast iron Fan material Polypropelene up to 112, cast iron for 132,160, aluminium for 180 to 200 Accessories Nil Paint & shade NC base RAL 5012 shade Bearing type Greasing facility Open type bearings for 80 to 200. No online greasing facility for up to 160 Frame. Online greasing facility for 180 to 225


Primo Series


primo series

Description:
Overview:
Ambient Temperature -10 to +50C Altitude Not exceeding 1000mtrs above mean sea level. Atmosphere Non corrosive & non hazardous Relative Humidity Up to 100% Voltage 415V10% , 3 ph. Frequency 50Hz 5% Combined Variation 10% Duty S1 (continuous) Service factor 1.0

Features:  Starting DOL for all (single entry upto 132,double entry for 160 with links) Or Star delta for frames 112 & above. Permissible starts/hr Cold successive - 4 , Hot successive - 3 , Equally spread - 6 Loading at reduced volts 75% Rated volts for 5mins Insulation / temp.rise Class `F' / 70C Direction of rotation Bi-directional No. Of leads 3 up to 100 & 6 for frame 112 & above. Connection Star: up to 90 frame and 6 & 8 pole ratings of 100 frame Delta: 2 & 4 pole ratings of 100 frame & 112 and above all ratings Degree of protection IP 55 Method of cooling IC 411 T.box position RHS looking from driving end towards DE Bearing life 40,000 working hours. For direct drive Vibration Normal class as per IS 12075. Noise As per IS 12065. Construction Foot, 'B' flange, 'C' Flange , Foot cum 'B' flange, Foot cum 'C' Flange Frame sizes PRIMO 63 to 160 Shaft extension Single cylindrical extension as per IS 1231 Body material Aluminium (Diecast) up to 112, cast iron for 132 to 160 T.box material Nylon 6 up to 132, Aluminium (die cast) for 160 Fan material Polypropelene Accessories Nil Paint & shade NC base RAL 5012 shade Bearing type and Greasing facility Pre lubricated sealed bearings No online greasing facility


Rerolling Mill Duty Motor


rerolling mill duty motor (1)

Description:
Overview:
Ambient Temperature 0 to +45C Altitude Not exceeding 1000mtrs above mean sea level. Atmosphere Non corrosive & non hazardous Relative Humidity Up to 100% Voltage 415V10% (Can also be offered upto 650V) Frequency 50Hz. 5% Combined Variation Any combination of voltage and frequency

Features:  Starting Stator Rotor Starter/Liquid Rotor Starter Permissible starts/hr. 2 Hot Or 3 Cold or 4 Equally spread Loading at reduced volts These motors are designed to run at 75% of rated supply voltage for a duration of five minutes. Insulation / temp.rise Class F/F Temp rise Stator/Rotor Class B/F Direction of rotation Bi-directional No. Of leads TR 5&6 > ST: 6 and RT: 3 Rest 3 / 3 Degree of protection IP23 Method of cooling IC01 T.box position Left hand side when viewed from non-drive end, reversible assembly at site is not possible. Terminal box arrangement For KCW 450 & 500: Stator 43506201, Rotor 43521599. For KCW 560: Stator 41102205, Rotor 43506101. Terminal box rotatable through 3600 in steps of 180 (i.e cable entry possible from top or buttom) Bearing life(90% survival basis) Lithium based grease to "Grade 3" as per IS: 7623 for 4 pole & above motors. Lubricant Direct drives: 40,000 working hours.(Based on 90% survival life) Vibration Normal class as per IS: 12075. Noise As per IS: 12065. Shaft extension. Single cylindrical extension as per IS: 1231. Body material Mild Steel T.box material Mild Steel Fan material Mild Steel Accessories Refer to Kirloskar Electric engineering department. Paint & shade Epoxy "RAL BLUE" to shade plate K-102 Bearing type and Greasing facility Antifriction rolling contact (Ball & Roller) Online greasing facility for all frames


Laminated Yoke DC Motors


laminated yoke dc motors


Features:  Small 0.75 to 300 80 to 250 Medium 150 to 1500 280 to 630 Large 720 to 6500 710 to 1000 by centre height up to 3100 MM by rotor diameter

Specification: Standards BS 5000/IS 4722 Insulation CLASS F/CLASS H Armature Voltage 110 to 1000 volts Field Voltage 180 to 360 volts Cooling IC 01/06/0041/0666/W37A86/17/44 Protection IP 23/44/54 Mounting B3/B35/B5/V1/V5

Aise Series Mill Duty Motors


aise series mill duty motors


Features:  kW Range 1.5 to 970 kW Frame Size 802 to 824

Specification: Standards BS 5000/IS 4722 Insulation Class F/Class H Armature Voltage 110 to 1000 Volts Field Voltage 180 to 360 Volts Cooling IC 01/06/0041/0666/W37A86/17/44 Protection IP 23/44/54 Mounting B3/B35/B5/V1/V5

Solid Yoke DC Motors




Features:  kW Range 1.5 to 600 kW Frame Size 112 to 560

Specification: Standards BS 5000/IS 4722 Insulation Class F/Class H Armature Voltage 110 to 1000 Volts Field Voltage 180 to 360 Volts Cooling IC 01/06/0041/0666/W37A86/17/44 Protection IP 23/44/54 Mounting B3/B35/B5/V1/V5

KDS


agri_kds

Description:
Overview:
These pumps can withstand voltage fluctuations from 180-240 volts. These have dynamically balanced rotating parts to ensure minimum vibrations. Cast iron impeller, delivery casing, these pumps are suitable for gardening and small farm irrigation, agri for clear water handling, water supply for agri, used in apartments, buildings and hotels.

Features:  High speed monoblock pump Flatter efficiency curves for efficient operation Designed for automatic air release during priming Dynamically balanced rotating parts ensuring minimum vibration during running Gland Packed / Mechanical Seal

Specification: Head range Upto 76 m Discharge range Upto 72 lps Power rating 0.37 ? 22 kW (0.5 ? 30 HP) Voltage range 300 ? 440 V (3 phase)
Downloads:KDS PDF

KS 6


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KS 7


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KS 8


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KDT+


kdtplus

Description:
Overview:
These pumps can withstand voltage fluctuations from 180-240 volts. These have flatter efficiency curve for efficient operation. These are designed to prevent overloading and motor burning and automatic air release during priming.

Features:  Flatter efficiency curve for efficient operation Designed to prevent overloading and motor burning Designed for automatic air release during priming Efficiency at par with international pumps Dynamically balanced rotating parts ensuring minimum vibration during running Class ?B?/ ?F? insulation Replaceable wearing parts Models with IP55 protection

Specification: Capacity up to 20 lps Head up to 110 m Power rating 3.7 to 15 kW (5 to 20 HP) Voltage 300-440 V (Three Phase)
Downloads:KDT+ PDF

KHDT+


khdt

Description:
Overview:
These pumps are available with belt drive and are electric motor or engine driven. These pumps are widely used in irrigation, sprinkler irrigation and water supply. Delivery size varies from 40 mm to 65 mm.

Features:  Suction lift upto 7.5 meters Top flat efficiency curve : minimum variation in efficiency in entire operating range Higher overall efficiency as compared to equivalent single stage pump Back to back mounting of impellers results in zero axial thrust and hence longer bearing life Can be run direct / through pulley with engine/ motor Dynamically balanced rotating parts, ensure minimum vibrations during running Replaceable wearing parts and hence longer life Designed to prevent overloading of motor Designed for automatic air release during priming

Specification: Head 24 to 104 meters Capacity 19.4 to 1.0 LPS Power Rating 3.7 kW to 15.0 kW ( 5.0 Hp to 20.0 Hp)

KU4 WINNER


ku4_winner_img

Description:
Overview:
These pumps are very light weight and compact in size. These pumps have higher efficiency and thus results in lower cost. These can be installed horizontally and can be installed with HDPE/UPVC/GI pipes. These are deigned to withstand voltage fluctuations from 280-430 volts. These are widely used in sprinkler and drip water irrigation system, farm houses, nurseries and gardening.

Features:  Pump bearings are water lubricated Suitable for high voltage fluctuation Wet type submersible motor Water ? cooled and water lubricated

Specification: Suitable for borewells diameter 100 mm and more Capacity up to 19 m3 /hr Head up to 249 m Power rating 0.37 kW to 4.0 kW (1 hp to 5 hp)
Downloads:KU4 WINNER PDF

KS 6


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KS 7


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KS 8


ks 6 7 8

Description:
Overview:
One of the best advantages of these pumps is huge saving in electrical consumption. These are designed to withstand wide voltage fluctuations. Non overloading power characteristics protect the motor. These pumps have dynamically rotating parts. Nitril rubber bushes ensure long life of pump even in muddy water. These are mainly used in fire fighting application. These also find wide usage in continuous supply of water in farming.

Features:  Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust free

Specification: Capacity 2400 to 60 lpm Head 5 to 306 m Power Rating 2.2 to 33 kW (3 to 45 HP)

KOS


submersible pumps kos

Description:
Overview:
Kirloskar KOS pump is an openwell submersible pump in cast iron construction. It has wide applications in agriculture and domestic segment.

Features:  Pump bearings are water lubricated Wet type submersible motor Water-cooled and water lubricated

Specification: Delivery size up to 100 mm (4) Capacity up to 110 m3 /hr Head up to 64 m Power rating 2.2 kW to 7.5 kW (3 hp to 10 hp)
Downloads:KOS PDF

KOS-M


submersible pumps kosm

Description:
Overview:
These pumps are designed for underwater applications and hence no need of priming and foot valve. These are easy to install and can withstand voltage variation from 350-440 volts. These are designed to prevent overloading and motor burning. These pumps find great use in submerged pumps in fountains, wells, sumps, and water links, water supply for domestic use in high rise apartments and in industries for clear water handling. Designed for underwater applications with CED coated wetted components for long life and rust free operation.

Features:  Designed for underwater applications: no need for priming and foot valve Easy installation - foundation and installation platform not required Can withstand wide voltage fluctuations from 160 to 260 Volts Non overloading power characteristics: no fear of motor burning out Dynamically balanced rotating parts ensure minimum vibrations Replaceable wear and tear parts and hence longer life Easy maintenance and spares availability: needs only one spanner for maintenance CED coated wetted components for long life and rust free operations More hygienic operations for drinking water

Specification: Technical Specifications Head : 8 to 38 metres Capacity : 11 to 0.4 LPS Power Ratings : 0.37 to 1.5 kW (0.5 to 2.0 HP) Voltage Range : 160 to 260 V Material of Construction (Standard Supply) Impeller : Cast Iron Delivery Casing : Cast Iron Motor Body : Cast Iron Shaft : Stainless Steel
Downloads:KOS-M PDF

KSIL / KCIL


ksil kcil

Description:
Overview:
Kirloskar KSIL, KCIL are vertical multistage centrifugal pumps. The in-line design enables installation of the pump in horizontal one pipe systems. The suction and discharge ports are of same dimension and are in the same horizontal plane. This arrangement insures a compact design and calls for a simpler piping systems.

Features:  Energy Efficient Compact and Aesthetical Design Corrosion Resistant Reliable Sealing Ease of Maintenance Durable Light Weight Low Noise Level

Specification: Delivery size 32 mm, 42 mm, 65 mm Capacity from 0.4 to 28 m?/hr Head 10 to 249 m
Downloads:KSIL / KCIL PDF

DB


db

Description:
Overview:
With a back pull out design these pumps are gland packed or mechanically sealed and are used for air conditioning, booster service, fire fighting and sprinkler system. Delivery size varies from 32 mm to 150 mm.

Features:  Conforming to DIN 24255 Back pull-out design Gland packed / Mechanical seal 50HZ / 60 HZ availability

Specification: Delivery size up to 150 mm Capacity up to 550 m? /hr Head up to 100 m Temperature (-) 10 ?C to 100 ?C
Downloads:DB PDF

CE


ce

Description:
Overview:
These pumps are of single stage with back pull out type suitable for 3500 rpm. These are either gland packed or mechanically sealed and delivery size can be up to 125 mm. These are very useful in air conditioning, water supply, fire-fighting and booster services.

Features:  Confirming to DIN 24256 and ISO 2858 Single stage with back pull-out type design Suitable for 3500 rpm Gland Packed / Mechanical Seal

Specification: Delivery size up to 125 mm Capacity up to 660 m? /hr Head up to 100 m Temperature up to (-) 10 ?C to 140 ?C
Downloads:CE PDF

CPHM


cphm

Description:
Overview:
These pumps can be driven by electric motor or engine. The impellers are of enclosed type and are balanced statically and dynamically. The casing has axial suction and top centre line delivery. Smooth hydraulic passages ensure high efficiency.

Features:  Conforming to DIN 24256, ISO 2858 Back pull-out design Gland Packed / Mechanical Seal 50 Hz / 60 Hz availability

Specification: Delivery size up to 200 mm Capacity up to 750 m3 /hr Head up to 150 m Temperature (-) 30 ?C to 90 ?C
Downloads:CPHM PDF

KH


kh

Description:
Overview:
These pumps are electric motor/engine driven and are used for irrigation, sprinkler irrigation and water supply. Delivery size varies from 25 mm to 50 mm.

Features:  coming soon

Specification: coming soon