Logo

Oil

BHR/ BHQ/ BHM/ BHMa/ BHA


no image

Description:
Overview:
Theses pumps are constructed rigidly to ensure vibration free operation. Hydraulic design is being updated with our continuous R&D efforts to meet requirements of higher efficiency and lower submergence, taking care of other parameters such as, high reliability and optimum system design.

Features:  Vibration-free performance Low submergence No priming required Dry pit/Wet pit arrangement available Direct drive/Right angle gear drive Impeller pull-out/Non-pull-out Bowl pull-out/Non-pull-out Gland packed / Mechanical seal 50Hz / 60Hz availability

Applications:  Water supply Pumps Irrigation Pumps Cooling tower Thermal and Nuclear power plants Steel, Cement industries Refineries Sea water on off-shore platforms Condensate extraction Fire fighting Pumps Flood control Dry Docks

Specification: Delivery size up to 2200 mm Capacity up to 40,000 m3 /hr Head up to 200 m

SCT


no image

Description:
Overview:
These are horizontally axially split casing, single stage, double suction or single suction pumps with horizontal shaft and detachable stuffing box called insert with horizontal axially split volute type. The impeller is accurately balanced by double or single suction. These pumps are used in handling water with slight impurities, petroleum refineries, conditioning and refrigeration system and so on.

Features:  Gland packed / Mechanical seal 50HZ / 60 HZ availability

Applications:  Water/Liquids with slight impurities Petroleum refineries Air-conditioning and refrigeration systems Fire protection systems and mining Pump axis horizontal or vertical

Specification: Delivery size up to 350 mm Capacity up to 4500 m3 /hr Head up to 330 m Temperature (-) 10 ?C to 100 ?C
Downloads:SCT PDF

SCT Extended


no image

Description:
Overview:
These are horizontally axially split casing, single stage, double suction or single suction pumps with horizontal shaft and detachable stuffing box called insert with horizontal axially split volute type. The impeller is accurately balanced by double or single suction. These pumps are used in handling water with slight impurities, petroleum refineries, conditioning and refrigeration system and so on.

Features:  Gland packed / Mechanical seal 50HZ / 60 HZ availability

Applications:  Water/Liquids with slight impurities Petroleum refineries Air-conditioning and refrigeration systems Fire protection systems and mining Pump axis horizontal or vertical

Specification: Delivery size up to 350 mm Capacity up to 4500 m3 /hr Head up to 330 m Temperature (-) 10 ?C to 100 ?C

DSM/ DSMT


no image

Description:
Overview:
These pumps are horizontally mounted having axially split casing. They can either be single stage or double stage. These are designed with single suction with a single volute operating at 50 Hz or 60 Hz. These pumps are used in urban water supply, industries, irrigation, air conditioning and so on.

Features:  Gland packed / Mechanical seal 50HZ / 60 HZ availability

Applications:  Water supply Air-conditioning Power plants Mine drainage Irrigation Fire fighting

Specification: Delivery size up to 150 mm Capacity up to 470 m3 /hr Head up to 180 m Temperature (-) 10 ?C to 90 ?C
Downloads:DSM/ DSMT PDF

UP / UPL / UPH / UP (T)


no image

Description:
Overview:
These pumps are gland packed and have mechanical seal. These are mainly used in water supply, irrigation, power plants and can have delivery size up to 1100 mm.

Features:  Gland packed / Mechanical seal 50HZ / 60 HZ availability

Applications:  Water Supply Irrigation Air-conditioning Power plants Paper, Sugar, Textile mills Fire fighting

Specification: Delivery size up to 1100 mm Capacity up to 20,000 m? /hr Head up to 160 m Temperature (-) 10 ?C to 90 ?C

I-HT


no image

Description:
Overview:
iHT pumps are horizontal split case single/double stage centrifugal pumps. All single stage pumps are provided with double suction type impeller. Both single stage/double stage pumps are fitted with DIN 24960 cavity mechanical seal. The impeller/s is/are centrally placed on a sturdy designed shaft and the entire rotating assembly is dynamically balanced to provide a smooth, trouble free, longer and efficient operation.

Features:  Highly efficient - low operation cost Compact size and less floor space Low down time - quickly fixable Low prime mover cost Lowest pumping - project cost Dual Drive to reduce downtime

Applications:  Suitable for Fire fighting Primary & secondary HVAC application High pressure boosting system Dewatering in mines Cooling tower Recirculation Desalination Water supply Paper plant Steel plant for high pressure injection Sugar plant Industrial utility water application

Specification: Delivery Sizes Upto 300 mm Discharge 30-1300 m3 /hr Head 30 to 250 m Speed 2900 rpm Temperature 8 0 C - 90 0C
Downloads:I-HT PDF

RKB


no image

Description:
Overview:
RKB is a multistage centrifugal side suction, vertical delivery, horizontal pump with diffuser type casing. Pump shaft is supported in anti-friction bearings. Enclosed impellers are of radial flow type provided with balancing holes. These pumps have standard lubrication of grease and are suitable for coupling with electric motors.

Features:  Gland Packed / Mechanical Seal 50 Hz / 60 Hz availability

Applications:  Fire-fighting Booster Service Mine Dewatering Boiler feed

Specification: Delivery size up to 250 mm Capacity up to 850 m3 /hr Heads up to 850 m Temperature (-) 40 ?C to 140 ?C
Downloads:RKB PDF

DB


no image

Description:
Overview:
With a back pull out design these pumps are gland packed or mechanically sealed and are used for air conditioning, booster service, fire fighting and sprinkler system. Delivery size varies from 32 mm to 150 mm.

Features:  Conforming to DIN 24255 Back pull-out design Gland packed / Mechanical seal 50HZ / 60 HZ availability

Applications:  Air Conditioning Sprinkler systems Fire fighting Booster service

Specification: Delivery size up to 150 mm Capacity up to 550 m? /hr Head up to 100 m Temperature (-) 10 ?C to 100 ?C
Downloads:DB PDF

CE


no image

Description:
Overview:
These pumps are of single stage with back pull out type suitable for 3500 rpm. These are either gland packed or mechanically sealed and delivery size can be up to 125 mm. These are very useful in air conditioning, water supply, fire-fighting and booster services.

Features:  Confirming to DIN 24256 and ISO 2858 Single stage with back pull-out type design Suitable for 3500 rpm Gland Packed / Mechanical Seal

Applications:  Air conditioning Fire fighting Booster services Water supply Sprinkler system Handling clear and turbid water up to 3000 ppm

Specification: Delivery size up to 125 mm Capacity up to 660 m? /hr Head up to 100 m Temperature up to (-) 10 ?C to 140 ?C
Downloads:CE PDF

CPHM


no image

Description:
Overview:
These pumps can be driven by electric motor or engine. The impellers are of enclosed type and are balanced statically and dynamically. The casing has axial suction and top centre line delivery. Smooth hydraulic passages ensure high efficiency.

Features:  Conforming to DIN 24256, ISO 2858 Back pull-out design Gland Packed / Mechanical Seal 50 Hz / 60 Hz availability

Applications:  Booster Service Fire fighting Air-conditioning

Specification: Delivery size up to 200 mm Capacity up to 750 m3 /hr Head up to 150 m Temperature (-) 30 ?C to 90 ?C
Downloads:CPHM PDF